id,row_type,item,item_label,run,include,include_label,type,derived_by,who,who_type,date,value_printed,unit_printed,watts,wh,formula,source_id,source_url,read_in_source,quote,detail,headline_for_item,plotted b01,published figure,brain_power,"Whole adult brain, power",,brain,Whole brain only,ESTIMATE,,Balasubramanian (PNAS),academic,2021-08,~20,W,20,,,balasubramanian2021,https://doi.org/10.1073/pnas.2107022118,,energy budget of 20 W,A review of where the brain spends energy; the 20 W figure is the budget it uses for the whole brain.,,Y b02,published figure,brain_power_range,"Whole adult brain, power (range)",,brain,Whole brain only,ESTIMATE,,Balasubramanian (PNAS),academic,2021-08,17 W to 20 W,W,17,,,balasubramanian2021,https://doi.org/10.1073/pnas.2107022118,,17 W to 20 W derived from glucose uptake in the brain,"Same paper: the part of the brain budget derived from glucose uptake; low end 17 W, high end 20 W (row value = low end; the high end is in detail).",,N b03,published figure,brain_part,"Cortical grey matter, power",,brain-part,Part of the brain (cortical grey matter),ESTIMATE,,"Levy and Calvert, via Balasubramanian (PNAS)",academic,2021-08,about 3,W,3,,,balasubramanian2021,https://doi.org/10.1073/pnas.2107022118,,cortical gray matter consumes about 3 W of power,"Cortical grey matter only, out of the 17 to 20 W for the whole brain; the rest powers the other parts and is lost as heat in their calculation.",,Y b04,published figure,brain_power,"Whole adult brain, power",adult male,brain,Whole brain only,ESTIMATE,IQ Metrics conversion to watts,Kuzawa et al. (PNAS),academic,2014-09,167.0 g/d and 1.88 times adult,g glucose per day,16.0022,,"adult g/day = 167.0 / 1.88; kcal/day = g x 3.72; W = kcal/day x 4,184 J / 86,400 s",kuzawa2014,https://doi.org/10.1073/pnas.1323099111,,167.0 g/d and 146.1 g/d in males and females,"Adult male brain, glucose only: the paper prints the childhood peak (167.0 g per day in males at 5.2 years) and that it is 1.88 times the adult value.",,Y b05,published figure,brain_child,"Child brain at its peak, power","male, 5.2 y",brain,Whole brain only,ESTIMATE,IQ Metrics conversion to watts,Kuzawa et al. (PNAS),academic,2014-09,"167.0 (male, 5.2 years)",g glucose per day,30.0841,,"W = 167.0 g/day x 3.72 kcal/g x 4,184 J/kcal / 86,400 s",kuzawa2014,https://doi.org/10.1073/pnas.1323099111,,peaks at 5.2 y of age at 167.0 g/d and 146.1 g/d in males and females,"Child brain at its peak daily glucose use, male, glucose only.",,Y b06,published figure,brain_child,"Child brain at its peak, power","female, 5.2 y",brain,Whole brain only,ESTIMATE,IQ Metrics conversion to watts,Kuzawa et al. (PNAS),academic,2014-09,"146.1 (female, 5.2 years)",g glucose per day,26.3191,,"W = 146.1 g/day x 3.72 kcal/g x 4,184 J/kcal / 86,400 s",kuzawa2014,https://doi.org/10.1073/pnas.1323099111,,peaks at 5.2 y of age at 167.0 g/d and 146.1 g/d in males and females,"Child brain at its peak daily glucose use, female, glucose only.",,Y b07,published figure,brain_power,"Whole adult brain, power",,brain,Whole brain only,ESTIMATE,IQ Metrics conversion to watts,Herculano-Houzel (PLoS ONE),academic,2011-03,516,kcal per day (86 billion neurons),24.9878,,"W = 516 kcal/day x 4,184 J/kcal / 86,400 s",herculano2011,https://doi.org/10.1371/journal.pone.0017514,,"Human, 86 billion 6 497.9 717033 129 516",Estimated cost of a brain with 86 billion neurons from glucose use per neuron (5.79 x 10^-9 micromol per neuron per minute).,,Y b08,published figure,brain_share,Brain share of body energy,,brain,Whole brain only,ESTIMATE,,Raichle and Gusnard (PNAS),academic,2002-08,about 20,% of the body's oxygen and calories,,,,raichle2002,https://doi.org/10.1073/pnas.172399499,,"about 20% of the oxygen and, hence, calories consumed by the body","Share of the whole body's energy use, not a power.",,N b09,published figure,body_power,"Whole body, power",,body,Whole body,STATEMENT,IQ Metrics conversion to watts,US Food and Drug Administration,agency,2024-03,"2,000",calories (kcal) a day,96.8519,,"W = 2,000 kcal/day x 4,184 J/kcal / 86,400 s",fda,https://www.fda.gov/food/nutrition-facts-label/calories-nutrition-facts-label,,"2,000 calories a day is used as a general guide for nutrition advice","Food energy a day used as a general guide (an intake, not a measured resting rate).",,Y b10,published figure,body_power,"Whole body, power",,body,Whole body,ESTIMATE,IQ Metrics calculation,IQ Metrics,IQ Metrics,2026-11,20 W / 20%,W,100,,W = 20 W / 0.20,raichle2002,https://doi.org/10.1073/pnas.172399499,,"about 20% of the oxygen and, hence, calories consumed by the body",The whole-body power implied if a 20 W brain is 20% of the body's consumption (Raichle and Gusnard use oxygen at rest).,,Y b11,published figure,brain_split,Where grey-matter energy goes,,brain,Whole brain only,ESTIMATE,,Attwell and Laughlin (JCBFM),academic,2001-10,47% and 34%,of grey-matter signalling energy (rodent),,,,attwell2001,https://doi.org/10.1097/00004647-200110000-00001,,"Action potentials and postsynaptic effects of glutamate are predicted to consume much of the energy (47% and 34%, respectively), with the resting potential consuming a smaller amount (13%)","Where the energy of rodent grey matter goes: action potentials 47%, postsynaptic effects 34%, resting potential 13%, glutamate recycling 3%.",,N a01,published figure,text_answer,One chatbot text answer,Gemini Apps,full,"Server, idle capacity and data-centre overhead (full stack)",MEASUREMENT,,Google (Elsworth et al.),company,2025-05,0.24,Wh per median Gemini Apps text prompt,,0.24,,elsworth2025,https://arxiv.org/abs/2508.15734,,the median energy consumption for a Gemini Apps text prompt in May 2025 is 0.24 Wh,"Fleet-wide measurement in May 2025 of the median text prompt: AI accelerators 0.14, host CPU and memory 0.06, idle machines 0.02, data-centre overhead 0.02 Wh.",yes,Y a02,published figure,text_answer,One chatbot text answer,Gemini Apps,chips,AI chips only,MEASUREMENT,,Google (Elsworth et al.),company,2025-05,0.10,Wh per median Gemini Apps text prompt (narrower boundary),,0.1,,elsworth2025,https://arxiv.org/abs/2508.15734,,the calculated energy consumption is only 0.10 Wh per prompt,"The same prompts counted with a narrower, earlier-style boundary (mainly active AI accelerators, on more highly used machines).",,Y a03,published figure,text_answer,One chatbot text answer,ChatGPT,unstated,Not stated,STATEMENT,,"OpenAI (Altman, blog)",company,2025-06,0.34,Wh per average ChatGPT query,,0.34,,altman2025,https://blog.samaltman.com/the-gentle-singularity,,the average query uses about 0.34 watt-hours,"A sentence in a CEO blog post; no method, query length, hardware or model mix is published. The saved page prints no date line (June 2025 from the post's listing and the papers that cite it).",,Y a04,published figure,text_answer,One chatbot text answer,GPT-4o,facility,"Server plus data-centre overhead (cooling, power conversion)",ESTIMATE,,Epoch AI (You),independent,2025-02,0.3,Wh per typical GPT-4o query,,0.3,,epoch2025,https://epoch.ai/gradient-updates/how-much-energy-does-chatgpt-use,,typical ChatGPT queries using GPT-4o likely consume roughly 0.3 watt-hours,"FLOP-based estimate: about one second of H100 time at 1,500 W (server and data-centre overhead included) and 70% of peak; 500 output tokens.",,Y a05,published figure,text_answer,One chatbot text answer,ChatGPT (2023 scenario),unstated,Not stated,ESTIMATE,,"de Vries (Joule), read in Oviedo et al.",academic,2023-10,2.9,Wh per ChatGPT query,,2.9,,oviedo2025,https://arxiv.org/abs/2509.20241,oviedo2025,Estimate Average ChatGPT query 2.9,Scenario estimate on 2023 hardware assumptions; the Joule paper itself was behind a bot check (HTTP 403) and was not read. Epoch AI quotes it as about 3 Wh.,,Y a06,published figure,text_answer,One chatbot text answer,BLOOM (research API),server,Chips plus host CPU and memory,MEASUREMENT,IQ Metrics division of two printed numbers,"Luccioni, Viguier and Ligozat",academic,2022-12,"914 kWh over 230,768 requests","Wh per request (BLOOM, 176B parameters)",,3.96069,"Wh per request = 914 kWh x 1,000 / 230,768 requests",luccioni2023,https://arxiv.org/abs/2211.02001,,consumed 914 kWh of electricity,"One research deployment of BLOOM on a cloud instance for about 18 days, 558 requests an hour, no batching; GPU, CPU and memory; includes the idle time between requests.",,Y a07,published figure,text_answer,One chatbot text answer,GPT-4o,facility,"Server plus data-centre overhead (cooling, power conversion)",ESTIMATE,,Jegham et al. (URI),academic,2025-11,0.42,Wh per short GPT-4o prompt,,0.42,,jegham2025,https://arxiv.org/abs/2505.09598,,Our framework estimates 0.42 Wh,Modelled from public API speed data and assumed hardware; short prompt = 100 input and 300 output tokens; 0.37 Wh without data-centre overhead.,,Y a08,published figure,text_answer,One chatbot text answer,GPT-5 (minimal reasoning),facility,"Server plus data-centre overhead (cooling, power conversion)",ESTIMATE,,Jegham et al. (URI),academic,2025-11,0.67,"Wh per short GPT-5 prompt, minimal reasoning",,0.67,,jegham2025,https://arxiv.org/abs/2505.09598,,"a short, minimal reasoning query consumes only 0.67 Wh","Same method as a07, for GPT-5 with the lowest reasoning setting.",,Y a09,published figure,text_answer,One chatbot text answer,models above 200B parameters,facility,"Server plus data-centre overhead (cooling, power conversion)",ESTIMATE,,Oviedo et al. (Microsoft),company,2025-09,0.31 (IQR 0.16 to 0.60),"Wh per query, median of models above 200B parameters",,0.31,,oviedo2025,https://arxiv.org/abs/2509.20241,,we estimate a median energy of 0.31 Wh/query,"Bottom-up estimate from token throughput, an 8-GPU node at 70% of peak power and data-centre overhead (PUE 1.05 to 1.40), assuming H100 and FP8.",,Y a10,published figure,text_answer,One chatbot text answer,Llama 3.1 70B,chips,AI chips only,MEASUREMENT,,"ML.ENERGY (Univ. of Michigan), read in Oviedo et al.",academic,2025-10,0.04,"Wh per query (Llama 3.1 70B, leaderboard v3.0)",,0.04,,oviedo2025,https://arxiv.org/abs/2509.20241,oviedo2025,Median energy per query for 4xH100 using BF16 reported as 0.04 Wh,"GPU energy only, 361 output tokens on average, batched serving; read in the Oviedo table, not in the leaderboard itself.",,Y a11,published figure,text_answer,One chatbot text answer,Llama 3.1 405B,chips,AI chips only,MEASUREMENT,,"ML.ENERGY (Univ. of Michigan), read in Oviedo et al.",academic,2025-10,0.21,"Wh per query (Llama 3.1 405B, leaderboard v3.0)",,0.21,,oviedo2025,https://arxiv.org/abs/2509.20241,oviedo2025,Median energy per query using FP8 reported as 0.21 Wh,"GPU energy only, 367 output tokens on average, batched serving; read in the Oviedo table.",,Y a12,published figure,text_answer,One chatbot text answer,Llama 3.1 70B (batch size 1),chips,AI chips only,MEASUREMENT,,"AI Energy Score, read in Oviedo et al.",academic,2025-06,1.72,"Wh per query (Llama 3.1 70B, batch size 1)",,1.72,,oviedo2025,https://arxiv.org/abs/2509.20241,oviedo2025,We adjusted for quantization as 1.72 Wh/1.7=1.01,"GPU energy only, one request at a time, no batching or serving engine (Oviedo et al. call it a non-production setting); the 1.72 Wh is the raw figure before their FP8 adjustment.",,Y a13,published figure,text_long,One long query (long input or long reasoning),GPT-4o (10k tokens in),facility,"Server plus data-centre overhead (cooling, power conversion)",ESTIMATE,,Epoch AI (You),independent,2025-02,around 2.5,"Wh for a query with a 10,000-token input",,2.5,,epoch2025,https://epoch.ai/gradient-updates/how-much-energy-does-chatgpt-use,,would substantially increase the cost per query to around 2.5 watt-hours,Same method as a04; the input is about a short paper or a long magazine article.,,Y a14,published figure,text_long,One long query (long input or long reasoning),GPT-4o (100k tokens in),facility,"Server plus data-centre overhead (cooling, power conversion)",ESTIMATE,,Epoch AI (You),independent,2025-02,almost 40,"Wh for a query with a 100,000-token input",,40,,epoch2025,https://epoch.ai/gradient-updates/how-much-energy-does-chatgpt-use,,would require almost 40 watt-hours of energy,"About 200 pages of text as input; the value used is 40 (printed as ""almost 40"").",,Y a15,published figure,text_long,One long query (long input or long reasoning),models above 200B parameters (long),facility,"Server plus data-centre overhead (cooling, power conversion)",ESTIMATE,,Oviedo et al. (Microsoft),company,2025-09,3.91 (IQR 2.15 to 7.05),"Wh per query, test-time scaling (15 times longer than typical)",,3.91,,oviedo2025,https://arxiv.org/abs/2509.20241,,the median energy rises 13 to 3.91 Wh,"Bottom-up estimate for queries 15 times longer than a typical one, models above 200B parameters.",,Y a16,published figure,text_long,One long query (long input or long reasoning),DeepSeek-R1,facility,"Server plus data-centre overhead (cooling, power conversion)",ESTIMATE,,Oviedo et al. (Microsoft),company,2025-09,10.6 (IQR 4.29 to 21.7),Wh per DeepSeek-R1 query,,10.6,,oviedo2025,https://arxiv.org/abs/2509.20241,,DeepSeek-R1 consumes 10.6 Wh,"Same bottom-up method as a09, for a reasoning model with long outputs.",,Y a17,published figure,text_long,One long query (long input or long reasoning),DeepSeek-R1 (B200),chips,AI chips only,MEASUREMENT,,"ML.ENERGY (Univ. of Michigan), read in Oviedo et al.",academic,2025-10,7.45,"Wh per query (DeepSeek-R1 on B200, leaderboard v3.0)",,7.45,,oviedo2025,https://arxiv.org/abs/2509.20241,oviedo2025,Adjusted to H100 as 7.45 Wh*2.8=20.9,"GPU energy only, 11,287 output tokens on average, FP8 on B200 chips; read in the Oviedo table.",yes,Y a18,published figure,text_long,One long query (long input or long reasoning),GPT-5 (high reasoning),facility,"Server plus data-centre overhead (cooling, power conversion)",ESTIMATE,,Jegham et al. (URI),academic,2025-11,33.8,"Wh per long GPT-5 prompt, high reasoning",,33.8,,jegham2025,https://arxiv.org/abs/2505.09598,,"a long, high-reasoning query reaches an average of 33.8 Wh","Same method as a07; long prompt = 10,000 input and 1,500 output tokens before reasoning tokens.",,Y a19,published figure,text_task,One short model call (10 new tokens),text generation models,server,Chips plus host CPU and memory,MEASUREMENT,"IQ Metrics: kWh per 1,000 = Wh per call","Luccioni, Jernite and Strubell (FAccT)",academic,2023-11,0.047 (SD 0.03),"kWh per 1,000 inferences, text generation",,0.047,"Wh per call = kWh per 1,000 inferences (1 kWh = 1,000 Wh, divided by 1,000)",luccioni2024,https://arxiv.org/abs/2311.16863,,text generation 0.047 0.03,"Mean over the models tested; each call generates only 10 new tokens; GPU, CPU and memory on one node of 8 A100 GPUs (the other GPUs' idle power is included).",yes,Y a20,published figure,text_task,One short model call (10 new tokens),summarisation models,server,Chips plus host CPU and memory,MEASUREMENT,"IQ Metrics: kWh per 1,000 = Wh per call","Luccioni, Jernite and Strubell (FAccT)",academic,2023-11,0.049 (SD 0.01),"kWh per 1,000 inferences, summarisation",,0.049,"Wh per call = kWh per 1,000 inferences",luccioni2024,https://arxiv.org/abs/2311.16863,,summarization 0.049 0.01,Mean over the models tested; same set-up as a19.,,Y i01,published figure,image,One generated image,image generation models (mean),server,Chips plus host CPU and memory,MEASUREMENT,"IQ Metrics: kWh per 1,000 = Wh per image","Luccioni, Jernite and Strubell (FAccT)",academic,2023-11,2.907 (SD 3.31),"kWh per 1,000 inferences, image generation, mean",,2.907,"Wh per image = kWh per 1,000 images",luccioni2024,https://arxiv.org/abs/2311.16863,,image generation 2.907 3.31,"Mean over the image-generation models tested (image size varies by model); GPU, CPU and memory.",yes,Y i02,published figure,image,One generated image,image generation models (median),server,Chips plus host CPU and memory,MEASUREMENT,"IQ Metrics: kWh per 1,000 = Wh per image","Luccioni, Jernite and Strubell (FAccT)",academic,2023-11,1.35,"kWh per 1,000 inferences, image generation, median",,1.35,"Wh per image = kWh per 1,000 images",luccioni2024,https://arxiv.org/abs/2311.16863,,than image generation (1.35 kWh),Median over the image-generation models tested.,,Y i03,published figure,image,One generated image,least efficient image model,server,Chips plus host CPU and memory,MEASUREMENT,"IQ Metrics: kWh per 1,000 = Wh per image","Luccioni, Jernite and Strubell (FAccT)",academic,2023-11,11.49,"kWh per 1,000 inferences, least efficient image model",,11.49,"Wh per image = kWh per 1,000 images",luccioni2024,https://arxiv.org/abs/2311.16863,,(11.49 kWh),The least efficient image-generation model tested; the paper puts it at around half a smartphone charge per image.,,Y v01,published figure,video,One generated video clip,AnimateDiff,server,Chips plus host CPU and memory,MEASUREMENT,"IQ Metrics sum of the GPU, CPU and RAM columns","Delavande, Pierrard and Luccioni (Hugging Face)",company,2025-09,0.115 + 0.016 + 0.008,Wh per clip: GPU + CPU + RAM (AnimateDiff),,0.139,Wh per clip = GPU Wh + CPU Wh + RAM Wh,delavande2025,https://arxiv.org/abs/2509.19222,,AnimateDiff 0.68 0.002 0.115 0.001 0.016 0.0001 0.008 0.00003,"Open model on one GPU node at default settings: 16 frames at 10 per second, 512 x 512. The paper prints the three columns; we add them.",yes,Y v02,published figure,video,One generated video clip,LTX-Video 0.9.7,server,Chips plus host CPU and memory,MEASUREMENT,"IQ Metrics sum of the GPU, CPU and RAM columns","Delavande, Pierrard and Luccioni (Hugging Face)",company,2025-09,3.16 + 0.32 + 0.19,Wh per clip: GPU + CPU + RAM (LTX-Video 0.9.7),,3.67,Wh per clip = GPU Wh + CPU Wh + RAM Wh,delavande2025,https://arxiv.org/abs/2509.19222,,LTX-Video-0.9.7-dev 9.7 0.01 3.16 0.006 0.32 0.002 0.19 0.001,"Open model on one GPU node at default settings: 121 frames at 24 per second, 512 x 704. The paper prints the three columns; we add them.",,Y v03,published figure,video,One generated video clip,CogVideoX-5B,server,Chips plus host CPU and memory,MEASUREMENT,"IQ Metrics sum of the GPU, CPU and RAM columns","Delavande, Pierrard and Luccioni (Hugging Face)",company,2025-09,21.6 + 2.4 + 1.3,Wh per clip: GPU + CPU + RAM (CogVideoX-5B),,25.3,Wh per clip = GPU Wh + CPU Wh + RAM Wh,delavande2025,https://arxiv.org/abs/2509.19222,,CogVideoX-5B 124 0.4 21.6 0.05 2.4 0.03 1.3 0.004,"Open model on one GPU node at default settings: 49 frames at 8 per second, 480 x 720. The paper prints the three columns; we add them.",,Y v04,published figure,video,One generated video clip,Mochi-1,server,Chips plus host CPU and memory,MEASUREMENT,"IQ Metrics sum of the GPU, CPU and RAM columns","Delavande, Pierrard and Luccioni (Hugging Face)",company,2025-09,44.7 + 4.6 + 2.8,Wh per clip: GPU + CPU + RAM (Mochi-1),,52.1,Wh per clip = GPU Wh + CPU Wh + RAM Wh,delavande2025,https://arxiv.org/abs/2509.19222,,Mochi-1-preview 263 0.5 44.7 0.2 4.6 0.01 2.8 0.01,"Open model on one GPU node at default settings: 84 frames at 30 per second, 480 x 848. The paper prints the three columns; we add them.",,Y v05,published figure,video,One generated video clip,WAN2.1 1.3B,server,Chips plus host CPU and memory,MEASUREMENT,"IQ Metrics sum of the GPU, CPU and RAM columns","Delavande, Pierrard and Luccioni (Hugging Face)",company,2025-09,78.8 + 7.4 + 4.3,Wh per clip: GPU + CPU + RAM (WAN2.1 1.3B),,90.5,Wh per clip = GPU Wh + CPU Wh + RAM Wh,delavande2025,https://arxiv.org/abs/2509.19222,,WAN2.1-T2V-1.3B 410 0.5 78.8 0.1 7.4 0.4 4.3 0.01,"Open model on one GPU node at default settings: 81 frames at 15 per second, 720 x 1280. The paper prints the three columns; we add them.",,Y v06,published figure,video,One generated video clip,WAN2.1 14B,server,Chips plus host CPU and memory,MEASUREMENT,"IQ Metrics sum of the GPU, CPU and RAM columns","Delavande, Pierrard and Luccioni (Hugging Face)",company,2025-09,359.7 + 35.6 + 19.8,Wh per clip: GPU + CPU + RAM (WAN2.1 14B),,415.1,Wh per clip = GPU Wh + CPU Wh + RAM Wh,delavande2025,https://arxiv.org/abs/2509.19222,,WAN2.1-T2V-14B 1875 2.1 359.7 0.5 35.6 4.0 19.8 0.02,"Open model on one GPU node at default settings: 81 frames at 15 per second, 720 x 1280. The paper prints the three columns; we add them.",,Y s01,published figure,search,One web search,Google web search,unstated,Not stated,STATEMENT,"IQ Metrics: 0.0003 kWh x 1,000",Google (company blog),company,2009-01,"0.0003 kWh, or 1 kJ",per search,,0.3,"Wh = 0.0003 kWh x 1,000",google2009,https://googleblog.blogspot.com/2009/01/powering-google-search.html,,"0.0003 kWh of energy per search, or 1 kJ","The servers each query touches, plus work done before the search starts (such as building the index). 0.0003 kWh = 0.3 Wh; 1 kJ would be 0.28 Wh (the post rounds). The only first-party figure we found; it is from 2009.",yes,Y t01,published figure,training,One training run,GPT-3,facility,"Server plus data-centre overhead (cooling, power conversion)",ESTIMATE,"IQ Metrics: MWh x 1,000,000","Patterson et al. (Google, UC Berkeley)",academic,2021-04,"1,287",MWh,,1.287e+09,"Wh = MWh x 1,000,000",patterson2021,https://arxiv.org/abs/2104.10350,,"Energy Consumption (MWh) 7.5 85.7 232 24.1 179 1,287","Outside estimate for GPT-3 (10,000 V100 chips for 14.8 days); OpenAI has not published the energy. Includes measured-type system power and data-centre overhead.",,Y t02,published figure,training,One training run,GPT-3,facility,"Server plus data-centre overhead (cooling, power conversion)",ESTIMATE,IQ Metrics: power x hours,Epoch AI (notable models table),independent,2026-11,"5,100,759.6 W x 355.2 h",W x hours,,1.81179e+09,Wh = training power draw (W) x training time (hours),epoch-data,https://epoch.ai/data/ai-models,,"Epoch table row ""GPT-3 175B (davinci)"": training power draw 5100760 W, training time 355 h","Epoch's training power draw (chips x TDP x server overhead x data-centre PUE, at peak) times its training time, GPT-3 175B.",,Y t03,published figure,training,One training run,BLOOM,chips,AI chips only,ESTIMATE,"IQ Metrics: kWh x 1,000","Luccioni, Viguier and Ligozat",academic,2022-12,"433,196",kWh,,4.33196e+08,"Wh = kWh x 1,000",luccioni2023,https://arxiv.org/abs/2211.02001,,"Total energy used 433,196 kWh",BLOOM (176B): GPU hours times the GPU's 400 W TDP; the authors say real-time power could not be tracked. Idle and infrastructure power add about as much again (their measured split: 54% dynamic).,,Y t04,published figure,training,One training run,BLOOM,facility,"Server plus data-centre overhead (cooling, power conversion)",ESTIMATE,IQ Metrics: power x hours,Epoch AI (notable models table),independent,2026-11,"308,035.2 W x 2,808 h",W x hours,,8.64963e+08,Wh = training power draw (W) x training time (hours),epoch-data,https://epoch.ai/data/ai-models,,"Epoch table row ""BLOOM-176B"": training power draw 308035 W, training time 2808 h","Epoch's training power draw times training time, BLOOM-176B.",,Y t05,published figure,training,One training run,T5,facility,"Server plus data-centre overhead (cooling, power conversion)",ESTIMATE,"IQ Metrics: MWh x 1,000,000","Patterson et al. (Google, UC Berkeley)",academic,2021-04,86,"MWh (T5, 11B)",,8.57e+07,"Wh = MWh x 1,000,000",patterson2021,https://arxiv.org/abs/2104.10350,,"Energy Consumption (MWh) 7.5 85.7 232 24.1 179 1,287","Google's T5 (largest size, 11B parameters).",,Y t06,published figure,training,One training run,Meena,facility,"Server plus data-centre overhead (cooling, power conversion)",ESTIMATE,"IQ Metrics: MWh x 1,000,000","Patterson et al. (Google, UC Berkeley)",academic,2021-04,232,"MWh (Meena, 2.6B)",,2.32e+08,"Wh = MWh x 1,000,000",patterson2021,https://arxiv.org/abs/2104.10350,,"Energy Consumption (MWh) 7.5 85.7 232 24.1 179 1,287",Google's Meena chatbot model (2.6B parameters).,,Y t07,published figure,training,One training run,Switch Transformer,facility,"Server plus data-centre overhead (cooling, power conversion)",ESTIMATE,"IQ Metrics: MWh x 1,000,000","Patterson et al. (Google, UC Berkeley)",academic,2021-04,179,MWh (Switch Transformer),,1.79e+08,"Wh = MWh x 1,000,000",patterson2021,https://arxiv.org/abs/2104.10350,,"Energy Consumption (MWh) 7.5 85.7 232 24.1 179 1,287","Google's Switch Transformer (1,500B parameters, 0.1% active per token).",,Y t08,published figure,training,One training run,Llama 2 70B,chips,AI chips only,ESTIMATE,IQ Metrics: GPU hours x watts,"Meta (Llama 2 paper), converted by IQ Metrics",company,2023-07,"1,720,320 GPU hours at 400 W",GPU hours x W,,6.88128e+08,Wh = GPU hours x per-GPU watts,touvron2023,https://arxiv.org/abs/2307.09288,,70B 1720320 400 291.42,"Llama 2 70B: Meta prints GPU hours and a per-GPU power of 400 W; its text says interconnect, non-GPU servers and cooling are not counted.",,Y t09,published figure,training,One training run,Llama 2 70B,facility,"Server plus data-centre overhead (cooling, power conversion)",ESTIMATE,IQ Metrics: power x hours,Epoch AI (notable models table),independent,2026-11,"795,557.1 W x 1,728 h",W x hours,,1.37472e+09,Wh = training power draw (W) x training time (hours),epoch-data,https://epoch.ai/data/ai-models,,"Epoch table row ""Llama 2-70B"": training power draw 795557 W, training time 1728 h","Epoch's training power draw times training time, Llama 2-70B.",,Y t10,published figure,training,One training run,Llama 3.1 405B,chips,AI chips only,ESTIMATE,IQ Metrics: GPU hours x watts,"Meta (Llama 3.1 model card), converted by IQ Metrics",company,2024-07,30.84M GPU hours at 700 W,GPU hours x W,,2.1588e+10,Wh = GPU hours x per-GPU watts,llama31,https://github.com/meta-llama/llama-models/blob/main/models/llama3_1/MODEL_CARD.md,,"Llama 3.1 405B 30.84M 700 8,930 0","Llama 3.1 405B: Meta prints GPU hours and a per-GPU power of 700 W (peak capacity per GPU, adjusted for power usage efficiency).",,Y t11,published figure,training,One training run,Llama 3.1 405B,facility,"Server plus data-centre overhead (cooling, power conversion)",ESTIMATE,IQ Metrics: power x hours,Epoch AI (notable models table),independent,2026-11,"22,622,532 W x 2,142 h",W x hours,,4.84575e+10,Wh = training power draw (W) x training time (hours),epoch-data,https://epoch.ai/data/ai-models,,"Epoch table row ""Llama 3.1-405B"": training power draw 22622532 W, training time 2142 h","Epoch's training power draw times training time, Llama 3.1-405B.",,Y t12,published figure,training,One training run,Llama 3.1 70B,chips,AI chips only,ESTIMATE,IQ Metrics: GPU hours x watts,"Meta (Llama 3.1 model card), converted by IQ Metrics",company,2024-07,7.0M GPU hours at 700 W,GPU hours x W,,4.9e+09,Wh = GPU hours x per-GPU watts,llama31,https://github.com/meta-llama/llama-models/blob/main/models/llama3_1/MODEL_CARD.md,,"Llama 3.1 70B 7.0M 700 2,040 0","Llama 3.1 70B, same rule as t10.",,Y t13,published figure,training,One training run,GPT-4,facility,"Server plus data-centre overhead (cooling, power conversion)",ESTIMATE,IQ Metrics: power x hours,Epoch AI (notable models table),independent,2026-11,"19,944,368 W x 2,280 h",W x hours,,4.54732e+10,Wh = training power draw (W) x training time (hours),epoch-data,https://epoch.ai/data/ai-models,,"Epoch table row ""GPT-4 (Mar 2023)"": training power draw 19944368 W, training time 2280 h","Epoch's training power draw (about 19.9 MW) times training time, GPT-4 (March 2023 row; confidence ""Likely""). OpenAI has not published either input.",,Y t14,published figure,training,One training run,GPT-4,facility,"Server plus data-centre overhead (cooling, power conversion)",ESTIMATE,"IQ Metrics: GWh x 1,000,000,000","Morand, Nevéol and Ligozat (CNRS, Paris-Saclay)",academic,2026-09,32.8,GWh,,3.28e+10,"Wh = GWh x 1,000,000,000",morand2025,https://arxiv.org/abs/2510.09022,,Usage 27.4 10.2 2.7 Infra 5.4 2.0 0.5 Total 32.8,"GPT-4 training, server use 27.4 GWh plus data-centre infrastructure 5.4 GWh; modelled from Epoch AI data with a life-cycle tool (MLCA).",,Y t15,published figure,training,One training run,Gemini 1.0 Ultra,facility,"Server plus data-centre overhead (cooling, power conversion)",ESTIMATE,IQ Metrics: power x hours,Epoch AI (notable models table),independent,2026-11,"38,423,900 W x 2,400 h",W x hours,,9.22174e+10,Wh = training power draw (W) x training time (hours),epoch-data,https://epoch.ai/data/ai-models,,"Epoch table row ""Gemini 1.0 Ultra"": training power draw 38423900 W, training time 2400 h","Epoch's training power draw times training time, Gemini 1.0 Ultra (confidence ""Speculative"").",,Y t16,published figure,training,One training run,Grok 3,facility,"Server plus data-centre overhead (cooling, power conversion)",ESTIMATE,IQ Metrics: power x hours,Epoch AI (notable models table),independent,2026-11,"109,948,656 W x 2,160 h",W x hours,,2.37489e+11,Wh = training power draw (W) x training time (hours),epoch-data,https://epoch.ai/data/ai-models,,"Epoch table row ""Grok 3"": training power draw 109948656 W, training time 2160 h","Epoch's training power draw times training time, Grok 3 (confidence ""Likely"").",,Y t17,published figure,training,One training run,Grok 4,facility,"Server plus data-centre overhead (cooling, power conversion)",ESTIMATE,"IQ Metrics: GWh x 1,000,000,000",Epoch AI (Data Insight),independent,2025-09,310,GWh,,3.1e+11,"Wh = GWh x 1,000,000,000",epoch-grok4,https://epoch.ai/data-insights/grok-4-training-resources,,We estimate that training Grok 4 required 310 GWh of electricity,Grok 4: 246 million H100-hours x 700 W x 2.03 (non-GPU hardware) x 1.2 (PUE) x 0.75 (average against peak draw); the inputs rest on public statements about Grok 3 and assumptions.,,Y x01,published figure,context,"All data centres, one year","all data centres, 2024",sector,"All data centres, all uses",ESTIMATE,IQ Metrics: TWh x 10^12,IEA (Energy and AI),agency,2025-04,around 415,TWh in 2024,,4.15e+14,"Wh = TWh x 1,000,000,000,000",iea2025,https://www.iea.org/reports/energy-and-ai,,electricity consumption from data centres is estimated to amount to around 415 terawatt hours,"Electricity used by all data centres worldwide in 2024, all uses (not only AI), about 1.5% of global electricity.",,N k01,IQ Metrics calculation,brain_calc,Brain-side calculation,"Brain, one minute at 20 W",brain,Whole brain only,CALCULATION,IQ Metrics,IQ Metrics,IQ Metrics,2026-11,,,,0.333333,Wh = 20 W x 1/60 h,balasubramanian2021,https://doi.org/10.1073/pnas.2107022118,,,"Inputs: 20 W (b01), 16.0 W (b04), 25.0 W (b07), 1.88 (Kuzawa), typing 51.56 and aloud 183 words per minute (our study how-fast-do-humans-think).",,Y k02,IQ Metrics calculation,brain_calc,Brain-side calculation,"Brain, one hour at 20 W",brain,Whole brain only,CALCULATION,IQ Metrics,IQ Metrics,IQ Metrics,2026-11,,,,20,Wh = 20 W x 1 h,balasubramanian2021,https://doi.org/10.1073/pnas.2107022118,,,"Inputs: 20 W (b01), 16.0 W (b04), 25.0 W (b07), 1.88 (Kuzawa), typing 51.56 and aloud 183 words per minute (our study how-fast-do-humans-think).",,Y k03,IQ Metrics calculation,brain_calc,Brain-side calculation,"Brain, one day at 20 W",brain,Whole brain only,CALCULATION,IQ Metrics,IQ Metrics,IQ Metrics,2026-11,,,,480,Wh = 20 W x 24 h,balasubramanian2021,https://doi.org/10.1073/pnas.2107022118,,,"Inputs: 20 W (b01), 16.0 W (b04), 25.0 W (b07), 1.88 (Kuzawa), typing 51.56 and aloud 183 words per minute (our study how-fast-do-humans-think).",,Y k04,IQ Metrics calculation,brain_calc,Brain-side calculation,"Brain, one year at 20 W",brain,Whole brain only,CALCULATION,IQ Metrics,IQ Metrics,IQ Metrics,2026-11,,,,175320,Wh = 20 W x 24 h x 365.25 days,balasubramanian2021,https://doi.org/10.1073/pnas.2107022118,,,"Inputs: 20 W (b01), 16.0 W (b04), 25.0 W (b07), 1.88 (Kuzawa), typing 51.56 and aloud 183 words per minute (our study how-fast-do-humans-think).",,Y k05,IQ Metrics calculation,brain_calc,Brain-side calculation,Brain to age 20 at a constant 20 W,brain,Whole brain only,CALCULATION,IQ Metrics,IQ Metrics,IQ Metrics,2026-11,,,,3.5064e+06,Wh = 20 W x 24 h x 365.25 days x 20 years,balasubramanian2021,https://doi.org/10.1073/pnas.2107022118,,,"Inputs: 20 W (b01), 16.0 W (b04), 25.0 W (b07), 1.88 (Kuzawa), typing 51.56 and aloud 183 words per minute (our study how-fast-do-humans-think).",,Y k06,IQ Metrics calculation,brain_calc,Brain-side calculation,Brain to age 20 at 16.0 W,brain,Whole brain only,CALCULATION,IQ Metrics,IQ Metrics,IQ Metrics,2026-11,,,,2.8055e+06,"Wh = 16.0 W x 175,320 h",balasubramanian2021,https://doi.org/10.1073/pnas.2107022118,,,"Inputs: 20 W (b01), 16.0 W (b04), 25.0 W (b07), 1.88 (Kuzawa), typing 51.56 and aloud 183 words per minute (our study how-fast-do-humans-think).",,Y k07,IQ Metrics calculation,brain_calc,Brain-side calculation,Brain to age 20 at 25.0 W,brain,Whole brain only,CALCULATION,IQ Metrics,IQ Metrics,IQ Metrics,2026-11,,,,4.38086e+06,"Wh = 25.0 W x 175,320 h",balasubramanian2021,https://doi.org/10.1073/pnas.2107022118,,,"Inputs: 20 W (b01), 16.0 W (b04), 25.0 W (b07), 1.88 (Kuzawa), typing 51.56 and aloud 183 words per minute (our study how-fast-do-humans-think).",,Y k08,IQ Metrics calculation,brain_calc,Brain-side calculation,"Brain to age 20, ceiling at 1.88 times the adult rate",brain,Whole brain only,CALCULATION,IQ Metrics,IQ Metrics,IQ Metrics,2026-11,,,,6.59203e+06,"Wh = 3,506,400 Wh x 1.88 (Kuzawa 2014 peak ratio, male, applied to all 20 years: a ceiling, not an estimate)",balasubramanian2021,https://doi.org/10.1073/pnas.2107022118,,,"Inputs: 20 W (b01), 16.0 W (b04), 25.0 W (b07), 1.88 (Kuzawa), typing 51.56 and aloud 183 words per minute (our study how-fast-do-humans-think).",,Y k09,IQ Metrics calculation,brain_calc,Brain-side calculation,"Brain typing a 200-word answer at 51.56 words a minute, at 20 W",brain,Whole brain only,CALCULATION,IQ Metrics,IQ Metrics,IQ Metrics,2026-11,,,,1.293,"Wh = 20 W x (200 / 51.56 x 60 s) / 3,600 s",balasubramanian2021,https://doi.org/10.1073/pnas.2107022118,,,"Inputs: 20 W (b01), 16.0 W (b04), 25.0 W (b07), 1.88 (Kuzawa), typing 51.56 and aloud 183 words per minute (our study how-fast-do-humans-think).",,Y k10,IQ Metrics calculation,brain_calc,Brain-side calculation,"Brain reading a 200-word answer aloud at 183 words a minute, at 20 W",brain,Whole brain only,CALCULATION,IQ Metrics,IQ Metrics,IQ Metrics,2026-11,,,,0.3643,"Wh = 20 W x (200 / 183 x 60 s) / 3,600 s",balasubramanian2021,https://doi.org/10.1073/pnas.2107022118,,,"Inputs: 20 W (b01), 16.0 W (b04), 25.0 W (b07), 1.88 (Kuzawa), typing 51.56 and aloud 183 words per minute (our study how-fast-do-humans-think).",,Y k11,IQ Metrics calculation,brain_calc,Brain-side calculation,Whole body (100 W) typing a 200-word answer at 51.56 words a minute,body,Whole body,CALCULATION,IQ Metrics,IQ Metrics,IQ Metrics,2026-11,,,,6.465,"Wh = 100 W x (200 / 51.56 x 60 s) / 3,600 s",balasubramanian2021,https://doi.org/10.1073/pnas.2107022118,,,"Inputs: 20 W (b01), 16.0 W (b04), 25.0 W (b07), 1.88 (Kuzawa), typing 51.56 and aloud 183 words per minute (our study how-fast-do-humans-think).",,Y k12,IQ Metrics calculation,brain_calc,Brain-side calculation,Whole body (100 W) reading a 200-word answer aloud at 183 words a minute,body,Whole body,CALCULATION,IQ Metrics,IQ Metrics,IQ Metrics,2026-11,,,,1.8215,"Wh = 100 W x (200 / 183 x 60 s) / 3,600 s",balasubramanian2021,https://doi.org/10.1073/pnas.2107022118,,,"Inputs: 20 W (b01), 16.0 W (b04), 25.0 W (b07), 1.88 (Kuzawa), typing 51.56 and aloud 183 words per minute (our study how-fast-do-humans-think).",,Y